In Reply to: Re: [gentoo-user-fr] HS- Pb disque dur by Antoine Raillon
1 je met le résultat des smart mon tool,
2 si quelqu'un pouvait me faire une traduction
3
4 merci
5
6
7 astar:~# smartctl --all /dev/hda5
8 smartctl version 5.34 [i686-pc-linux-gnu] Copyright (C) 2002-5 Bruce Allen
9 Home page is http://smartmontools.sourceforge.net/
10
11 === START OF INFORMATION SECTION ===
12 Model Family: Western Digital Caviar family
13 Device Model: WDC WD800BB-00CAA1
14 Serial Number: WD-WCA8E4664997
15 Firmware Version: 17.07W17
16 User Capacity: 80,026,361,856 bytes
17 Device is: In smartctl database [for details use: -P show]
18 ATA Version is: 5
19 ATA Standard is: Exact ATA specification draft version not indicated
20 Local Time is: Wed Dec 28 13:26:09 2005 CET
21 SMART support is: Available - device has SMART capability.
22 SMART support is: Enabled
23
24 === START OF READ SMART DATA SECTION ===
25 SMART overall-health self-assessment test result: PASSED
26
27 General SMART Values:
28 Offline data collection status: (0x85) Offline data collection activity
29 was aborted by an interrupting
30 command from host.
31 Auto Offline Data Collection: Enabled.
32 Self-test execution status: ( 121) The previous self-test completed having
33 the read element of the test failed.
34 Total time to complete Offline
35 data collection: (3120) seconds.
36 Offline data collection
37 capabilities: (0x3b) SMART execute Offline immediate.
38 Auto Offline data collection
39 on/off support.
40 Suspend Offline collection upon new
41 command.
42 Offline surface scan supported.
43 Self-test supported.
44 Conveyance Self-test supported.
45 No Selective Self-test supported.
46 SMART capabilities: (0x0003) Saves SMART data before entering
47 power-saving mode.
48 Supports SMART auto save timer.
49 Error logging capability: (0x01) Error logging supported.
50 No General Purpose Logging support.
51 Short self-test routine
52 recommended polling time: ( 2) minutes.
53 Extended self-test routine
54 recommended polling time: ( 58) minutes.
55 Conveyance self-test routine
56 recommended polling time: ( 5) minutes.
57
58 SMART Attributes Data Structure revision number: 16
59 Vendor Specific SMART Attributes with Thresholds:
60 ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE
61 UPDATED WHEN_FAILED RAW_VALUE
62 1 Raw_Read_Error_Rate 0x000b 200 200 051 Pre-fail
63 Always - 0
64 3 Spin_Up_Time 0x0007 103 094 021 Pre-fail
65 Always - 3925
66 4 Start_Stop_Count 0x0032 099 099 040 Old_age
67 Always - 1373
68 5 Reallocated_Sector_Ct 0x0033 199 199 140 Pre-fail
69 Always - 3
70 7 Seek_Error_Rate 0x000b 200 200 051 Pre-fail
71 Always - 0
72 9 Power_On_Hours 0x0032 090 090 000 Old_age
73 Always - 7570
74 10 Spin_Retry_Count 0x0013 100 100 051 Pre-fail
75 Always - 0
76 11 Calibration_Retry_Count 0x0013 100 100 051 Pre-fail
77 Always - 0
78 12 Power_Cycle_Count 0x0032 099 099 000 Old_age
79 Always - 1362
80 196 Reallocated_Event_Count 0x0032 198 198 000 Old_age
81 Always - 2
82 197 Current_Pending_Sector 0x0012 200 200 000 Old_age
83 Always - 2
84 198 Offline_Uncorrectable 0x0012 200 200 000 Old_age
85 Always - 0
86 199 UDMA_CRC_Error_Count 0x000a 200 253 000 Old_age
87 Always - 4
88 200 Multi_Zone_Error_Rate 0x0009 200 200 051 Pre-fail
89 Offline - 0
90
91 SMART Error Log Version: 1
92 ATA Error Count: 224 (device log contains only the most recent five errors)
93 CR = Command Register [HEX]
94 FR = Features Register [HEX]
95 SC = Sector Count Register [HEX]
96 SN = Sector Number Register [HEX]
97 CL = Cylinder Low Register [HEX]
98 CH = Cylinder High Register [HEX]
99 DH = Device/Head Register [HEX]
100 DC = Device Command Register [HEX]
101 ER = Error register [HEX]
102 ST = Status register [HEX]
103 Powered_Up_Time is measured from power on, and printed as
104 DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
105 SS=sec, and sss=millisec. It "wraps" after 49.710 days.
106
107 Error 224 occurred at disk power-on lifetime: 1014 hours (42 days + 6 hours)
108 When the command that caused the error occurred, the device was
109 doing SMART Offline or Self-test.
110
111 After command completion occurred, registers were:
112 ER ST SC SN CL CH DH
113 -- -- -- -- -- -- --
114 40 51 08 c6 76 0e e3 Error: UNC 8 sectors at LBA = 0x030e76c6 = 51279558
115
116 Commands leading to the command that caused the error were:
117 CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
118 -- -- -- -- -- -- -- -- ---------------- --------------------
119 c8 00 08 bf 76 0e e3 00 03:29:41.450 READ DMA
120 c8 00 08 b7 76 0e e3 00 03:29:41.450 READ DMA
121 c8 00 02 b9 76 0e e3 00 03:29:41.450 READ DMA
122 c8 00 08 ef d2 b7 e2 00 03:29:41.050 READ DMA
123 c8 00 08 4f 43 bb e2 00 03:29:41.050 READ DMA
124
125 Error 223 occurred at disk power-on lifetime: 1014 hours (42 days + 6 hours)
126 When the command that caused the error occurred, the device was
127 doing SMART Offline or Self-test.
128
129 After command completion occurred, registers were:
130 ER ST SC SN CL CH DH
131 -- -- -- -- -- -- --
132 40 51 38 c6 76 0e e3 Error: UNC 56 sectors at LBA = 0x030e76c6 = 51279558
133
134 Commands leading to the command that caused the error were:
135 CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
136 -- -- -- -- -- -- -- -- ---------------- --------------------
137 c8 00 38 bf 76 0e e3 00 03:21:12.550 READ DMA
138 c8 00 40 b7 76 0e e3 00 03:21:09.550 READ DMA
139 ca 00 08 ef 1e 5c e2 00 03:21:08.000 WRITE DMA
140 ca 00 10 df 1e 5c e2 00 03:21:08.000 WRITE DMA
141 ca 00 08 e7 d2 fb e2 00 03:21:05.700 WRITE DMA
142
143 Error 222 occurred at disk power-on lifetime: 1014 hours (42 days + 6 hours)
144 When the command that caused the error occurred, the device was
145 doing SMART Offline or Self-test.
146
147 After command completion occurred, registers were:
148 ER ST SC SN CL CH DH
149 -- -- -- -- -- -- --
150 40 51 40 c6 76 0e e3 Error: UNC 64 sectors at LBA = 0x030e76c6 = 51279558
151
152 Commands leading to the command that caused the error were:
153 CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
154 -- -- -- -- -- -- -- -- ---------------- --------------------
155 c8 00 40 b7 76 0e e3 00 03:21:09.550 READ DMA
156 ca 00 08 ef 1e 5c e2 00 03:21:08.000 WRITE DMA
157 ca 00 10 df 1e 5c e2 00 03:21:08.000 WRITE DMA
158 ca 00 08 e7 d2 fb e2 00 03:21:05.700 WRITE DMA
159 ca 00 08 ff c2 fb e2 00 03:21:05.700 WRITE DMA
160
161 Error 221 occurred at disk power-on lifetime: 1014 hours (42 days + 6 hours)
162 When the command that caused the error occurred, the device was
163 doing SMART Offline or Self-test.
164
165 After command completion occurred, registers were:
166 ER ST SC SN CL CH DH
167 -- -- -- -- -- -- --
168 40 51 b8 c6 76 0e e3 Error: UNC 184 sectors at LBA = 0x030e76c6 = 51279558
169
170 Commands leading to the command that caused the error were:
171 CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
172 -- -- -- -- -- -- -- -- ---------------- --------------------
173 c8 00 b8 bf 76 0e e3 00 03:17:41.200 READ DMA
174 c8 00 40 6f c3 88 e2 00 03:17:41.200 READ DMA
175 c8 00 20 47 c3 88 e2 00 03:17:41.200 READ DMA
176 c8 00 18 2f c3 88 e2 00 03:17:41.200 READ DMA
177 c8 00 08 77 0a b6 e2 00 03:17:41.200 READ DMA
178
179 Error 220 occurred at disk power-on lifetime: 1014 hours (42 days + 6 hours)
180 When the command that caused the error occurred, the device was
181 doing SMART Offline or Self-test.
182
183 After command completion occurred, registers were:
184 ER ST SC SN CL CH DH
185 -- -- -- -- -- -- --
186 40 51 08 c6 76 0e e3 Error: UNC 8 sectors at LBA = 0x030e76c6 = 51279558
187
188 Commands leading to the command that caused the error were:
189 CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
190 -- -- -- -- -- -- -- -- ---------------- --------------------
191 c8 00 08 bf 76 0e e3 00 03:17:24.400 READ DMA
192 c8 00 08 b7 76 0e e3 00 03:17:24.400 READ DMA
193 c8 00 02 b9 76 0e e3 00 03:17:24.400 READ DMA
194 c8 00 08 4f 43 bb e2 00 03:17:24.400 READ DMA
195 c8 00 18 ff 42 89 e2 00 03:17:24.400 READ DMA
196
197 SMART Self-test log structure revision number 1
198 Num Test_Description Status Remaining
199 LifeTime(hours) LBA_of_first_error
200 # 1 Extended offline Completed: read failure 90% 1014
201 51279558
202 # 2 Short offline Completed without error 00% 166 -
203
204 Device does not support Selective Self Tests/Logging
205
206
207 On 12/28/05, Antoine Raillon <antoine.raillon@××××××.net> wrote:
208 > jm pp <jm.pppp@×××××.com> a écrit :
209 >
210 > 'jour ;p
211 >
212 > > qq un aurait un diagnotic
213 >
214 > Ca pour moi, c'est un dd mort et bien mort ;)
215 >
216 > Si tes logs kernels étaient pas sur ce disque, remonte les sur qqes
217 > jours, tu dois pouvoir trouver des erreurs similaires dedans qui
218 > t'indiqueront depuis quand il déconnait et essayait de te prévenir ;)
219 >
220 > pour ce qui est des données.. je ne sais pas si il existe qqchose
221 > comme easyrecovery (ou autre) sous linux, mais ca m'etonnerait bien que
222 > non. Sinon tu peux toujours tenter avec dd (la commande, pas
223 > l'abréviation ;p)
224 >
225 > bon courage !
226 >
227 > --
228 > Antoine Raillon <antoine.raillon@××××××.net>
229 >
230 >
231 > --
232 > gentoo-user-fr@g.o mailing list
233 >
234 >
235
236 --
237 gentoo-user-fr@g.o mailing list

Replies

Subject Author
Re: [gentoo-user-fr] Re: HS- Pb disque dur Benjamin LASSERRE <blasserre@××××.fr>