1 On Tue, Apr 28, 2009 at 6:40 PM, maxim wexler <blissfix@×××××.com> wrote:
2 >
3 > Hi group,
4 >
5 > Lookee here:
6 >
7 > kyzyl linux # apcaccess status
8 > APC      : 001,034,0852
9 > DATE     : Tue Apr 28 19:26:47 MDT 2009
10 > HOSTNAME : kyzyl
11 > RELEASE  : 3.12.4
12 > VERSION  : 3.12.4 (19 August 2006) gentoo
13 > UPSNAME  : kyzyl
14 > CABLE    : USB Cable
15 > MODEL    : Back-UPS ES 350
16 > UPSMODE  : Stand Alone
17 > STARTTIME: Tue Apr 28 15:47:20 MDT 2009
18 > STATUS   : ONLINE
19 > LINEV    : 120.0 Volts
20 > LOADPCT  :  71.0 Percent Load Capacity
21 > BCHARGE  : 100.0 Percent
22 > TIMELEFT :   2.8 Minutes
23 > MBATTCHG : 5 Percent
24 > MINTIMEL : 3 Minutes
25 > MAXTIME  : 0 Seconds
26 > LOTRANS  : 088.0 Volts
27 > HITRANS  : 139.0 Volts
28 > ALARMDEL : Always
29 > BATTV    : 13.4 Volts
30 > LASTXFER : Input frequency out of range
31 > NUMXFERS : 0
32 > TONBATT  : 0 seconds
33 > CUMONBATT: 0 seconds
34 > XOFFBATT : N/A
35 > STATFLAG : 0x07000008 Status Flag
36 > MANDATE  : 2007-10-16
37 > SERIALNO : 3B0742X02836
38 > BATTDATE : 2000-00-00
39 > NOMBATTV :  12.0
40 > FIRMWARE : 23.B1.D USB FW:B1
41 > APCMODEL : Back-UPS ES 350
42 > END APC  : Tue Apr 28 19:27:34 MDT 2009
43 >
44 > Only 2.8mins left? The UPS unit, fairly common I suspect, is a Back-UPS ES 350 and less than a year old. It only saw service once last year during an electric storm when the house power failed for a few minutes. Why isn't it charging. Or is it? It says BATTDATE 2000-00-00. Huh?
45 >
46 > I'd like to test it further but the apcupsd manual recommends at least 5mins time left. If I just unplug it from the back of the PC, will it charge? Is the battery caput?
47 >
48 > Maxim
49
50 Unplug all your electronic devices and plug in a lamp with a 100 Watt
51 incandescent light build. With the lamp on unplug the UPS from the