1 |
Hi folks, |
2 |
|
3 |
anybody using them? If so I have got a question. |
4 |
|
5 |
Except one thing, everything is handled fine by gentoo's start-up scripts. The |
6 |
exception is this: If NUT shuts the box down, a flag /etc/killpower is |
7 |
created. At the end of the shutdown process this flag determines whether the |
8 |
UPS itself is to be switched of by software. That is supposed to avoid |
9 |
complete depletion of the UPS - maybe by a monitor plugged into it directly. |
10 |
|
11 |
It seems to me that this flag never gets removed. So a manual "halt" also |
12 |
tries to switch off the UPS which might not be intended. |
13 |
|
14 |
Anybody else seeing this? |
15 |
|
16 |
Uwe |
17 |
|
18 |
-- |
19 |
Why do consumers keep buying products they will live to curse? |
20 |
-- |
21 |
gentoo-user@g.o mailing list |